DC Machinery choose Italy Oli brand vibrating motor for our shale shakers. Vibration motor is important components for shale shaker. How to maintain vibrating motor? The following is the brief introduction.

 

1 Before installing vibrator, turn off and lock out all energy sources to mounting structure according to ANSI standards.

2 If using a cutting torch or welding, test atmosphere for gas level or dust content.

3 Make sure mounting surface and vibrator are clean and free of debris, paint, and oxidation.

4 Before installing vibrator onto mount, apply thread sealing compound to all bolts.

5 Before operating, must check the bolts to confirm whether there is loose or not. Otherwise, we must screw bolts tight before running shaker.

6 The vibration motor should be under good lubrication during operation:

Motors before fixed on shaker, the bearing is filled with SKF specific lubricate grease, the temperature range is -40 ~ 200℃.

During running, every 2000 working hours user should makeup LGHP2 lubricate grease once. Every bearing can’t be filled over 25.8g.

To make sure bearing operated well, we must use LGHP2 grade high temperature lubrication grease. Before adding new lubrication grease we should clean the input hole.